<ErrorNumber>27026</ErrorNumber>
<ErrorFamily>Debris Removal</ErrorFamily>
<ErrorMessage>
DEB: Timeout: the pressure sensor output failed to stabilize
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>UDRC</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
</text></DescriptionText>
</OperatorAction>
<Cause>
Cause 1:  With the blower off the system is checking the pressure sensor(s) to see if they are stable. The system thinks that the pressure is fluctuating, and can't determine a stable reading to set the offset. Solution:  Unplug the sensing line(s) to the offending sensor and reset the output device. If the error is still present then the sensor is defective and must be replaced. If the error goes away then the pressure really is unstable and the cause must be determined. If the nozzle sensor is unstable, try cleaning the nozzle (see UDRC Techplanet site for detailed instructions):  http://techplanet.creo.com/output/heads/debris_removal/nav/proced.htmReboot device and try again.Replace the appropriate sensor.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:34:15 2008 PST
</Updated>
<Links>
</Links>
</Error>